Transformer Bushing
126kV Dry R.I.F. /R.I.P. Transformer Bushing(Draw Lead Type)

126kV Dry R.I.F. /R.I.P. Transformer Bushing(Draw Lead Type)

 

  • Dimension-table 1
  • Dimension-table 2
  • Electrical data
Dimension -table 1                         
FBRG
126/630-800
FBRG
L126/630-800
FBRG
126/1250
FBRGL
126/1250
Total   lengthL1980234019802340
Terminal blocksHole   number and
hole diameter
n1×d14x144x144x184x18
Hole distancea140405050
Panel surfaceb1×b280×8080×8080×8080×80
Panel thicknessδ12121212
Cable entry lengthL41750211017502110
Head   diameterd3128128128128
lead wire connection apertured828283232
Compound external insulationInsulation   diameterL11150115011501150
Creepage distanceS/U≥31≥31≥31≥31
Maximum umbrella
diameter
d9290290290290
FlangeOuter   diameter of
flange plate
d7400400400400
Center distance of
installing hole
a2350350350350
Hole number and
hole diameter
m×d26×246×246×246×24
Inner diameter of sealing surfaced4180180180180
Total   length of oil impregnated partL2445805445805
Core   diameter in oild148148148148
Oil   earthed lengthL304000400
Equalizing   ballL560606060
d5120120120120
Inner   diameter of contact tubed639393939
Casing   weightkg77887890

Note:The outline dimension of the product in the table is recommended,all size can be designed according to the needs of users. Only one kind of CT length is listed on the table, and the user can design the CT length according to the product requirements.With the changes of CT length, relevant dimensions also change.

Technical   standardsGB/T 4109-2008 IEC 60137 Ed.6.0
Rated   voltage126kV
Rated   current630-3150A
1min   power frequency dry(wet) voltage withstand460/550kV
Full-wave   impulse withstand voltage of lighting325kV
Under   1.05 times of maximum phase voltage tan δ≤0.004
Partial   discharge under the rated voltage≤10pC
Bending   resistant test load2000-3150N
The   minimum nominal creepage distance31mm/kV


Name: *
Content: *
   
Copyright

©2016. Shandong Chinsun Electrical Equipment Co.,Ltd. All Rights Reserved.

About us

Introduction

Product Details

Honor

Product

Transformer Bushing

Wall Bushing

GIS Bushing

Current Transformer

Contact

Address:
West Rongfeng road,Technology Industrial Park,
Zibo city, Shandong Province, China

Phone:
+86(533)7868868

http://www.cxdqkj.com

信箱 留言 微信 收藏