252kV Dry R.I.F. /R.I.P. Transformer Bushing(Draw Lead Type)

252kV Dry R.I.F. /R.I.P. Transformer Bushing(Draw Lead Type)




  • Dimension-table 1
  • Dimension-table 2
  • Electrical data
Dimension -table 1                         
FBRG
252/630-800
FBRGL
252/630-800
FBRG
252/1250
FBRGL
252/1250
FBRG
252/1600
FBRGL
252/1600
Total   lengthL353039303550395035503950
Terminal blocks

Hole number

and hole 

diameter

n1×d14x144x144x184x184x184x18
Hole distancea1404050505050
Panel surfaceb1×b280×8080×80100×100100×100100×100100×100
Panel thicknessδ121214141616
Cable entry lengthL4329536953295369532953695
Head   diameterd3285285285285285285
lead wire connection apertured8282832323636
Compound external insulationInsulation diameterL1224022402240224022402240
Creepage distanceS/U≥31≥31≥31≥31≥31≥31

Maximum 

umbrella

diameter
d9435435435435435435
Flange

Outer

diameter of

flange plate
d7550550550550550550

Center 

distance of

installing hole
a2500500500500500500

Hole number 

and hole 

diameter

m×d212×2412×2412×2412×2412×2412×24

Inner diameter

of sealing 

surface

d4300300300300300300
Total   length of oil impregnated partL2815121581512158151215
Core   diameter in oild260260260260260260
Oil   earthed lengthL3040004000400
Equalizing   ballL5130130130130130130
d5245245245245245245
Inner   diameter of contact tubed6656565656565
Casing   weightkg476508478514480520

Note:The outline dimension of the product in the table is recommended,all size can be designed according to the needs of users. Only one kind of CT length is listed on the table, and the user can design the CT length according to the product requirements.With the changes of CT length, relevant dimensions also change.

Technical standardsGB/T 4109-2008 IEC 60137 Ed.6.0
Rated voltage252kV
Rated current630-1600A
1min power frequency dry(wet) voltage withstand505(460)kV
Full-wave impulse withstand voltage of lighting1050kV
Operation impulse withstand voltage850kV
Under 1.05 times of maximum phase voltage tan δ≤0.004
Partial discharge under the rated voltage≤10pC
Bending resistant test load4000N
The minimum nominal creepage distance31mm/kV
Name: *
Content: *
   
Copyright

©2016. Shandong Chinsun Electrical Equipment Co.,Ltd. All Rights Reserved.